Connecting to an RTTrPM device

WYSIWYG contains drivers that enable you to “listen” to incoming RTTrPM data when connected to the updated RTTrPM network device in LIVE mode.

To connect to an RTTrPM device
  1. Run WYSIWYG and start a new file.
  2. Insert a venue, BlackTrax Trackables or Zones.
  3. Insert and attach objects to your BlackTrax Trackables or Zones.
  4. Patch the BlackTrax Trackables or Zones to Motion Patch Universes. See Quick Motion Patch Tool.
  5. Switch to LIVE mode.
  6. From the Options menu, choose Application Options.

Result: The Application Options window appears.

  1. In the Application Options window, click Additional Interfaces.
  2. From the Local Address drop-down list in the RTTrPM Interface section of the Additional Interfaces tab, select the IP address from which the incoming RTTrPM device data is being received by your computer.
  3. In the Group Address box type the IP address from group data transmissions.
  4. In the Port box type the port number used by the RTTrPM device connection.
  5. Click OK.

Result: A dialog box appears prompting to open the Device Manager, disconnect and reconnect for the change to take effect.

  1. Click OK to close the dialog box and the Application Options window.
  2. From the Managers menu, choose Device Manager.

Result: The Device Manager window appears.

  1. In the Device Manager window, click New.

Result: The Library Selection window appears.

  1. In the Library Selection window, search for RTTrPM (note spelling).
  2. Select the single search result and click Insert.
  3. With RTTrPM selected in the device list, click Properties.
  4. Bind the Universes you created to the incoming RTTrPM ports.
  5. When the binding is complete, click OK.
  6. In the Device Manager window, with RTTrPM selected in the device list, click Connect.
  7. Close the Device Manager window.

Result: You are now connected and WYSIWYG will begin reacting to incoming RTTrPM data.